Recommandé par l'IIF / Document IIF
Dispositif d'essai cryogénique pour la caractérisation du mesurage de débit par ultrasons.
A cryogenic test setup for characterization of ultrasonic flow measurement.
Numéro : 113
Auteurs : WINKLER T., BODENDORFER K., KLUPSCH M., RACKOW S., KADE A., FRIEDRICH S., WESER R., EHRLICH A.
Résumé
Metrological relevant flow measurement under cryogenic conditions is one of the most challenging tasks in process measurement. While the metrological requirements are defined in standards like OIML-R117-1/2, the realization of a cryogenic flow test bench for metrological control of the flow meter is far from standard work. Ultrasonic flow measurement offers the possibility to separate the influencing factors and to estimate the contribution of the different factors in dedicated experiments. One of these factors is the so called zero point error, which gives the deviation of the measurement with flow at rest. SICK as a manufacturer of ultrasonic flow meters aims to extend the use of its product portfolio to the cryogenic range. The ILK Dresden is accompanying the development phase with a test setup for the characterization of the ultrasonic transducer in Liquid Nitrogen (LN2). The final objective is to demonstrate the suitability of the transducer and the uncertainty contribution of the time measurement under cryogenic conditions.
Therefore, a laboratory-scale test setup was realized which provides both a stationary fluid without any disturbance and precise pressure and temperature conditions. The suitability of the transducers under cryogenic conditions was proved successfully showing a reasonable signal response. The system time delays were determined for both fluids. Hence, the comparability of the results for LN2 and water was shown which furthermore allows a transfer of measurement results under ambient conditions to an application under cryogenic conditions. Thus, the measurement with water is sufficient for the verification of the transducers, so that effort and costs can be saved without loss in accuracy.
Documents disponibles
Format PDF
Pages : 6 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A cryogenic test setup for characterization of ultrasonic flow measurement.
- Identifiant de la fiche : 30031046
- Langues : Anglais
- Source : Proceedings of the 17th IIR International Conference on Cryogenics, Dresden, Germany, april 25-28 2023
- Date d'édition : 25/04/2023
- DOI : http://dx.doi.org/10.18462/iir.cryo.2023.0113
Liens
Voir d'autres communications du même compte rendu (33)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Cryogénie: sécurité, instrumentation et métrologie
- Mots-clés : Mesure; Azote liquide; Débit; Ultrason; Cryogénie
-
Mesure de débit d'un fluide cryogénique. Exempl...
- Auteurs : PATHIER D.
- Date : 01/2015
- Langues : Français
- Source : Industries Agro-alimentaires - vol. 132 - n. 01-02
Voir la fiche
-
MESURES PAR ULTRASONS DE DEBITS DE LIQUIDES CRY...
- Auteurs : FORSTER M.
- Date : 1984
- Langues : Français
Voir la fiche
-
A sensitive cryogenic refractometer. Applicatio...
- Auteurs : BADOZ J., LE LIBOUX M., NAHOUM R., et al.
- Date : 05/1992
- Langues : Anglais
- Source : Rev. sci. Instrum. - vol. 63 - n. 5
Voir la fiche
-
Effect of gas mass flux on cryogenic liquid jet...
- Auteurs : INGEBO R. D.
- Date : 1992
- Langues : Anglais
- Source : Cryogenics - vol. 32 - n. 2
Voir la fiche
-
Experimental and numerical analysis of heat los...
- Auteurs : BOUKEFFA D., BOUMAZA M., FRANCOIS M. X., et al.
- Date : 06/2001
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 21 - n. 9
Voir la fiche