In this work, experimental tests were conducted on a domestic refrigerator to evaluate three faults with three levels: deterioration of the speed of the fan coupled to the condenser; degree of external fouling on the condenser; and area restriction on the rear cover of the refrigerator. The above, to analyze the effect of the type of fault on the performance of the refrigerator. Through a thermal analysis, it was observed that components such as the compressor and condenser presented a more noticeable variation in the thermal behavior of the refrigerant in the different faults. In fact, the fault corresponding to the fan speed was the one that caused the most inadequate performance in the refrigerator, compared to the refrigerator operating under normal conditions. The high level of this fault was reflected in an increase of 14.73 ◦C in the temperature of the refrigerant at the condenser inlet, it even caused an increase in the discharge pressure of 2.1 bar. Finally, this fault increased by 48% in energy consumption as well, which represented a 26% decrease in the coefficient of performance.
Documents disponibles
Format PDF
Pages : p. 290-299
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Fault analysis in a domestic refrigerator: Fan fault, condenser fouling, and area restriction.
- Identifiant de la fiche : 30032006
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 154
- Date d'édition : 10/2023
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.09.001
Liens
Voir d'autres articles du même numéro (33)
Voir la source
Indexation
-
Alternative energy test method for frost-free r...
- Auteurs : HERMES C. J. L., MELO C., KNABBEN F. T.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Peering into the cabinet: quantifying the energ...
- Auteurs : HARRINGTON L., AYE L., FULLER B., et al.
- Date : 08/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
Voir la fiche
-
Effects of the kitchen environment on the energ...
- Auteurs : SAHEB Y., CORDIER A., MONCHOUX F.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
Caracterização experimental de refrigeradores i...
- Auteurs : THIESSEN S., MELO C., KNABBEN F. T., et al.
- Date : 03/05/2016
- Langues : Portugais
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche
-
High-efficiency fan-motors for refrigerators.
- Auteurs : BAKER G. N.
- Date : 05/1997
- Langues : Anglais
- Source : Appl. Manuf. - vol. 45 - n. 5
Voir la fiche