Recommended by the IIR / IIR document
How to optimize the floating high pressure
Number: 0145
Author(s) : GUILPART J., NOTTURNO J., ALTAMIRANO A.
Summary
The floating High Pressure approach is very well known in industrial refrigeration. In most cases, it consists of letting the HP “float” a few degrees above the ambient temperature and to adjust the ventilation of the condensers to ensure the required heat rejection. However, a more comprehensive approach would deserve to be adopted in which the optimum trade-off between the reduction of the power input of the condenser’s fans and the increase of the power input of the compressor is identified. This paper presents the method, the optimization algorithm and the results obtained in an industrial configuration. Results show that several local optimal conditions exist depending on the operational constraints (e.g., the availability of the components, the running orders, the minimum acceptable VEV value, and the wet bulb temperature), but only the first must be sought to obtain interesting results.
Available documents
Format PDF
Pages: 10 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: How to optimize the floating high pressure
- Record ID : 30031699
- Languages: English
- Subject: Technology
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Publication date: 2023/08/21
- DOI: http://dx.doi.org/10.18462/iir.icr.2023.0145
Links
See other articles from the proceedings (492)
See the conference proceedings
Indexing
-
Toepassing van moderne regelmethoden in de koel...
- Author(s) : INFANTE FERREIRA C.
- Date : 1998/12
- Languages : Dutch
- Source: Koude & Luchtbehandeling - vol. 91 - n. 12
View record
-
Influence du dispositif de régulation sur les p...
- Author(s) : VENDEL E.
- Date : 2011/06
- Languages : French
- Source: Revue générale du Froid & du Conditionnement d'air - vol. 101 - n. 1114
View record
-
Optimierte Arbeitstemperaturregelung.
- Author(s) : WENDELBORN H.
- Date : 2007/08
- Languages : German
- Source: Kälte + Klimatechnik (Die) - vol. 60 - n. 8
View record
-
Analyse des gains énergétiques d'un automate ad...
- Author(s) : CLODIC D., LOYER J. C., FAYOLLE F., et al.
- Date : 2000/12/12
- Languages : French
- Source: Télégestion et automate programmable en froid. ELEC 2000 : recueil des conférences.
View record
-
L'impact d'une HP flottante bien maîtrisée.
- Author(s) : BORLEIN C., LE DUC V.
- Date : 2011/03
- Languages : French
- Source: La revue pratique du froid et du conditionnement d'air - n. 993
View record